POM series boilers are, blowing burner, cast iron sectioned, between the capacities 378 – 930 kW with proper burner connection, works with gas or liquid fuel in 11 different ( 6 – 16 sections) type. POM series boilers operating pressure is 6 bar maximum, and working temperature is 90 °C maximum. In POM series boilers,heat transfer surface areas are increased by the special wings in the burning room and chimney ways.This inceases the high heat transfer ability of cast iron boiler to the maximum level.

POM series boilers are cast iron sectioned boilers.This brings easy assembling and easy capacity increasing by adding sections to the boiler. The transportation and set up of the boiler is easy because boiler is assembled in boiler rooms It is easily to carry or shift position without breaking walls. POM series boilers are casted with special alloy, which is durable for heat extansions and changes, EN GJL200. They are long life boilers according to this special cast iron alloy.

With the help of horizontal and three pass specially designed sections burning gases pass three times in the boiler and transmits burning energy to the water inside the sections at high level. POM series boilers are high efficiency boilers. ( According to the fuel bottom heating value % 91 – 93 ). With this high efficiency and perfect isolation more energy is gained with less fuel. Heat loses are minimized on POM series boilers. By appropriate burning room, heat transfer surface, turbulator, collector and isolation high heat transfer and optimum flue gas emition results are provided.

Boiler sections are delivered as assembled or not assembled according to the boiler room specifications and dimensions.In not assembled deliveries, sections and assembling aparats are delivered on a pallet, cabins,isolation and other elements are delivered in a box.

FEATURES

  • Available in 11 models; 6 to 16 sections
  • High efficiency 3 pass design
  • High quality cast iron parts
  • Casing insulation with 80 mm thick glass wool mattress
  • High heat transfer capacity with flame delayer turbulators
  • Spacious combustion chamber with two side opening burner door (left and right)
  • High combustion performance with low exhaust emission
  • Special design thermix flange for giving high speed to return water
  • Easy temperature control
  • Ease to install, use and maintenance
  • Optional with automatic eco control panel
Series Name POM-06 POM-07 POM-08 POM-09 POM-10 POM-11 POM-12 POM-13 POM-14 POM-15 POM-16
Number Of Sections Pcs. 6 7 8 9 10 11 12 13 14 15 16
Heat Output kCal / h 325.000 385.000 435.000 485.000 525.000 570.000 615.000 665.000 715.000 755.000 800.000
kW 377,9 447.7 505,8 564 610,5 663 715 773 831 878 930
Heat İnput kCal / h 351.000 415.800 469.800 523.800 567.000 615.600 664.200 718.200 772.200 815.400 864.000
kW 408,1 483,5 546,3 609,1 659,3 716 772 835 898 948 1.005
Operating Temperature °C 90
Range Of Temperature Control °C 30-90 °C
Gas Side Resistence mbar 1,75-2,20 1,90-2,40 2,25-2,75 2,55-3,10 2,80-3,35 3,15-3,70 3,45-4,05 3,80-4,35 4,10-4,75 4,45-4,95 4,85-5,50
mmH2O 17,85 - 22,44 19,38 - 24,48 22,95 - 28,05 26,01 - 31,62 28,56 - 34,16 32,13 - 37,73 35,18 - 41,30 38,75 - 44,36 41,48 - 48,44 45,38 - 50,48 49,46 - 56,09
Maximum Operating Pressure bar 6
Boiler Water Content Itr 149,5 174 198,5 223 247,5 272 296 321 346 370 395
0,15 0,174 0,199 0,223 0,248 0 0 0 0 0,37 0
Exit Flue Connection Diameter mm 350
Combustion Chamber Dimensions Ø mm 501
L mm 910 1.070 1230 1.390 1555 17.110 1.870 2.030 2.190 2.350 2.510
Water Input - Output Connection (") DN 100 (4")
Gas Volume Of The Boiler dm³ (I) 341,74 400,71 459,68 518,65 577,62 637 695,56 754,53 813,5 872,47 931,44
0,342 0,401 0,46 0,519 0,578 1 0,696 0,775 0,814 0,872 0,931
Safety Temperature Limiter °C 100
Boiler Type ON / OFF
Fuel Type Gas Natural Gas (I2H)
Liquid F. Liquid Fuel (Extra Light Heat Oil)
Flue Gas Outlet Temperature Full Load °C 182-187 178-185 175-180 177-182 174-180 175-180 182-187 178-185 175-180 177-182 174-180
Part Load °C 165-172 164-170 161-167 165-170 164-170 165-170 165-172 164-170 161-167 165-170 164-170
Flue Gas Outlet Mass Flow Full Load kg / h 633 750 847 945 1023 1.110 1198 1295 1393 1470 1558
kg / sec. 0,1758 0,2083 0,0216 0,0261 0,0302 0 0,3327 0,3598 0,0216 0,0261 0,0302
Part Load kg / h 380 450 508 567 614 666 719 777 836 882 935
Pa/mbar 0
Buner Type Short Barrel
Buner Flange Connection Dimension mm 225
Standby Loss % 0,33 0,31 0,28 0,27 0,24 0 0,2 0,18 0,17 0,16 0,14
kCal / h 11.583 12.890 13.154 14.143 13.608 13.543 13.284 12.928 13.127 13.046 12.096
Cast Body Weight
Complete Weight
Gross Weight
kg 980 1.115 1.250 1.385 1.520 1.655 1.790 1.925 2.060 2.195 2.330
kg 1.020 1.160 1.300 1.440 1.580 1.720 1.860 2.000 2.140 2.280 2.420
kg 1.070 1.210 1.350 1.490 1.630 1.770 1.920 2.060 2.200 2.340 2.480